Add to Cart
TD60 T7F TAMURA Tin Wire Ceramic Body Thermal Cutoff Temperature Fuse Axial Lead Fuse
T6D TAMURA Thermal Fuse
Rated current:8-9A
Rated voltage:250V AC 50V DC
Rated operaying temperature:139℃
Component and Material
No. | Component | Material |
① | Fusible Alloy | Low meling point alloy |
② | Flux | Special resin |
② | Case | Ceramics |
④ | Sealant | Epoxy resin |
⑤ | Lead wire | Tin plated copper wire |
Model | Tf (C) | (C) | (A) | (V) | Th (C) | Tm (C) | Type |
T6D | 139 | 139+0/-7 | 8.0 | DC50 | 90 | 200 | Axial type |
9.0 | DC50 | 90 | 200 | Axial type |
Performance
The thermal-links must comply with the following test items and any other applicable requirements.
-1. Appearance and Dimension check
Test conditions: Visual, Micrometer or Caliper
Specific: The display should be legible with no remarkable fault, and the size should be within the specificed dimcnsions.
-2.Resistance test
Test conditions: The D.C. resistance be mcasured by putting the thermal-links body between less than 20mm by four terminal method.
-3. Functioning temperature test
Test conditions: The thermal-links soaking in oil bath which rise temperature at 0.5~ l.0C/min, and mcasure the oil temperaturc at functioning. Mcasurcment beginning temperature Tf -20°C,and the detection current are assumed to be less than 10mA.
Specific: Functioning within at +0°C,-79C of rated functioning temperature.
-4. Insulation resistance test
Test conditions: (a) Beforc functioning test .between case and lead wires
(b) After functioning test●between case and lead wires between lead wires
Specific: D.C. 100V,more than 1000MQ
-5. Diclectric withstand test
Test conditions: (a) Before functioning test *bctween case and lead wires
(b) After functioning test●between case and lead wires
(c) Afler functioning test● between lead wires
Specific: (a)(b) Apply D.C.1 100V continuity endure for I minutc. (Detection current 0.5mA)
(c) Apply D.C. 100V continuity endure for I minute. (Detection current 0.5mA)
-6.Humidity test
Test conditions: Measure the functioning temperature after left for 500 hours in the following temperature conditions.T6D [60C 95%RH]
Specific: Functioning within at +0°C,-109C of rated functioning tempcrature.
-7. Heat shock test
Test conditions: Measure the functioning temperature after left for per 30 minutes with 200 cycles in the following temperature conditions.T6D-L [-40°C-80°C]
Specific: Functioning within at +0°C,-10°C of rated functioning temperature.
T7F TAMURA Thermal Fuse
Rated current:1-3A
Rated voltage:125V 250V AC 50V DC
Rated operaying temperature:145℃
Unit : mm
A | B | C | D | E |
6.3+0.3 | 2.0+0.1 | 2.3 and under | 0.53+0.05 | 68+3.0(T口F ) |
38+3.0(TC ]F-C ) |
Model | Rated operating temperature Tf [°C ] | Operating temperature [°C ] | AC/DC | Rated voltage [V] | Rated voltage [ A] | Th [°C] | Tm [°C] | Commonly used temperature [°C ] |
T7F | 145 | 140+2 | AC | 250 | 1.0 | 1.0 | 200 | Max.115°C |
125 | 2.5 | 122 | 200 | Max.115°C | ||||
DC | DC | 3.0 | 115 | 200 | Max.80°C |
Approval | |||
UL C-UL | E73591 | E73591 | E73591 |
VDE | 40009915 | 40009915 | 40009915 |
CCC | 2008010205274844 | - | - |
PSE | JET5823-32001-1005 | - | - |
KTL | SU05028-10004 | - | - |